Test Results for FM
T&E Results for QM
Test Condition Specification Performance
Pre Environmental tests at SRC Visual inspection Normal
Continuity & Isolation tests Within specification
Power Module Checks  
Input power monitoring test Measured current drawn is 110 mA against the specification of 120mA±10%
ON command threshold tests Width at amplitude of 5V = 1.10ms Amplitude at width of 64ms = 1.1V
OFF command threshold tests Width at amplitude of 5V = 1.15ms Amplitude at width of 64ms = 1.2V
Functionality verification tests The drift was calculated and the drift was found to be 42% The specification for drift is ≤50%
Programmable parameters test SAA outputs was found to conform to the expected, in a qualitative manner
Invalid command response test The detector was found not to respond to the invalid commands
Power Supply variation test Performance was found to be normal
Environmental Tests EMI tests Normal
Thermal Cycling Cold soak & Hot soak test The performance was found to be normal
Vibration Test The performance was found to conform with the pre-vibration performance
Thermo Vacuum Test The pattern of variation of output count w.r.t. input commands was found to be as expected, qualitatively
Post-Environmental Tests All the tests referred in Pre Environmental tests at SRC were conducted The performance of the FM module conformed to Initial SRC results